Our products: vertical turbine pump, vertical wet pit pump, vertical oil sump pump, vertical condensation pump, right Angle gearbox
date:2023/10/10 23:55:25 source: Vertical Turbine Pump Manufacturer and Vertical Suspension Pump Prices Provider visits()
The VTP series vertical turbine pump summary The VTP series vertical turbine pump is a single suction and multi-stage vertical guide vane water pump, which adopts mixed flow and centrifugal impellers, and is matched with high-performance self-lubricating water guide bearings, with a long service life. It can be used with a corner gearbox and can be driven by a diesel engine. The underwater length can be customized according to user requirements. This series of vertical turbine long shaft pumps is an advanced and mature long shaft pump series product developed by absorbing advanced experience in the design and manufacturing of vertical long shaft pumps at home and abroad, and combining with domestic market demand. It has the characteristics of high efficiency, reliable operation, fast start, compact structure, and small footprint. It is suitable for conveying clean water, rainwater, seawater and other media in industries such as electricity, metallurgy, firefighting, mining, steel, and municipal engineering. It is widely used in flood control and drainage, dock water treatment, cooling services, seawater and raw water, industrial process pumps, public design circulating water, condenser circulating water pumps, flushing dust, firefighting, deep well water lifting, and municipal tap water. technical parameter Maximum flow rate: 25000 m3/h (110000 gallons per minute) Maximum head: 456m (1500 feet) Power range: 1.5~3400kW Temperature range: -32~200 ℃ Pressure range:~2.5 MPa Execution standards GB/T5657 Technical Conditions for Centrifugal Pumps ······ Class III; GB/T13008 Technical specifications for mixed flow pumps and axial flow pumps. Application scope Steel, metallurgy, mining, chemical, papermaking, and tap water industries Electric heating station boiler circulating water Urban water supply and drainage fresh water and seawater intake engineering Shipbuilding industry Municipal industry Deep well water extraction Rainwater discharge Permeable water discharge Usage conditions 1. During the operation of the water pump, a certain submergence depth must be ensured, and the minimum submergence depth value can be found in the pump's safety installation dimension diagram. 2. Water should not contain any oily substances. 3. Water should not contain excessive corrosive minerals. 4. The sand content in water shall not exceed 0.01% by weight. The pH value of water should be between 6.5 and 8.5, and special customization is required if it exceeds this range. 6. The well should be upright. figure drawing Driver type The VTP series vertical turbine pump has four driving forms: 1) directly driven by a regular vertical motor; Ii) Directly driven by a vertical hollow shaft motor; Iii) Equipped with diesel engines or steam turbines for variable speed drive through a right angle gearbox; IV) Equipped with a horizontal motor and driven by a right angle gearbox for variable speed. classification The pump equipment mainly consists of three parts: pump body components, lifting pipe components, and pump seat components. The first two parts are located underground, and the pump seat part is located above the well. VTP vertical turbine long shaft pumps are divided into the following four products based on impeller type and driving mode: 1. LC type single stage or multi-stage centrifugal pump or mixed flow pump (corresponding to API 610 VS1 pump) for high head, where the vertical multi-stage guide vane centrifugal pump can be extended to a vertical cylindrical bag pump (corresponding to API 610 VS6 pump). 2. HLB (K) single stage mixed flow pump (oblique flow pump) for high flow rate and medium head. 3. ZLB single stage axial flow pump (corresponding to API 610 VS3 pump) for high flow rate and low head. vertical turbine pump driven by a right angle gearbox for firefighting and offshore platforms or areas with insufficient power supply. LC series vertical long shaft turbine pump Performance range Maximum flow rate: 8800 cubic meters per hour (39600 gallons per minute) Maximum head: 450 meters (1500 feet) Maximum temperature: 200 ℃ (388 ℉) HLB (K) series vertical single stage mixed flow turbine pump (oblique flow turbine pump) Performance range Maximum flow rate: 25000 cubic meters per hour (110000 gallons per minute) Maximum head: 70 meters (210 feet) ZLB series vertical long shaft single stage axial flow turbine pump Performance range Maximum flow rate: 20000 cubic meters per hour (90000 gallons per minute) Maximum head: 12 meters (36 feet) Materials Of Major Parts The VTP series vertical turbine pump has a smaller ground area, making it safer and more reliable than submersible pumps; No need for irrigation and can be started at any time; Has a unique sand removal structure that can adapt to water containing sand; By using a variety of different materials, it can adapt to various media. VTP series vertical turbine pump material: stainless steel 304316316L, cast steel ZG235-450, cast iron QT400-18 or HT250, duplex steel 2205 or 2507. Main parts Clear water Sewage and impurity water Seawater and other corrosive media Configuration 1 Configuration 2 Suction bell mouth HT250 QT500-7 or ZG2Cr13 HT250Ni2Cr ZG00Cr17Ni14Mo2 or ZG00Cr22Ni5Mo3N impeller ZG230-450 ZG2Cr13 or ZG0Cr13Ni4Mo ZG1Cr18Ni9Ti ZCuZn16Si4 或 ZG00Cr17Ni14Mo2 or ZG00Cr22Ni5Mo3N Impeller chamber ZG230-450 ZG2Cr13 or ZG0Cr13Ni4Mo ZG1Cr18Ni9Ti ZCuZn16Si4 或 ZG00Cr17Ni14Mo2 or ZG00Cr22Ni5Mo3N Sealing ring ☆ HT250 or 0Cr18Ni9 ZG2Cr13 or ZG0Cr13Ni4Mo ZCuZn16Si4 ZCuZn16Si4 or ZG00Cr17Ni14Mo2 or ZG00Cr22Ni5Mo3N Guide vane body HT250 QT500-7 OR ZG2Cr13 or ZG0Cr13Ni4Mo ZG1Cr18Ni9Ti ZG00Cr17Ni14Mo2 or ZG00Cr22Ni5Mo3N External connecting pipe and protective pipe Q235B Q235B 1Cr18Ni9Ti ZG00Cr17Ni14Mo2 or ZG00Cr22Ni5Mo3N Axis ☆ 45 or 2Cr13 40Cr or 2Cr13 1Cr18Ni9Ti 00Cr22Ni5Mo3N 45 or 0Cr18Ni9 0Cr18Ni9 or 2Cr13 1Cr17Ni2 00Cr17Ni14Mo2 or 00Cr22Ni5Mo3N Shaft sleeve ☆ Guide bearing☆ Filled with PTFE/nitrile rubber/bronze/Theron Guide bearing body HT250 or Q235B HT250 or QT500-7 ZG1Cr18Ni9Ti ZG00Cr17Ni14Mo2 or ZG00Cr22Ni5Mo3N middle Coupling 45 or 2Cr13 40Cr or 2Cr13 1Cr17Ni2 00Cr17Ni14Mo2 or 00Cr22Ni5Mo3N outlet elbow Q235B Q235B 1Cr18Ni9Ti 00Cr17Ni14Mo2 or 00Cr22Ni5Mo3N Motor base Q235B Q235B Q235B Q235B Note: The material can be selected according to user requirements. The ones with ☆ are vulnerable parts, and the semi open impeller structure does not have sealing ring parts. Other materials are available at the request of clients.Cast iron is suitable only for closed type impeller. Structural characteristics ◆Water outlet elbows larger than 10 inches are welded components. Suitable for high-temperature liquid pump transportation. ◆The external connecting pipe and guide vane body are both connected by flanges and positioned with a stop, which is convenient for assembly and disassembly during maintenance. ◆The external connecting pipe with stop positioning has low cost, convenient maintenance, and fewer malfunctions. ◆The transmission shafts are connected by key type couplings for easy maintenance. ◆When pumping media with particulate matter, a closed transmission shaft design with protective tubes can be used, and external flushing water can be used to flush the guide bearings, suitable for pumping corrosive and abrasive media. ◆There are various bearing materials available for selection, such as rubber, dragon, carbon fiber, ceramics, etc. ◆The replaceable shaft sleeve surface has been hardened to extend its lifespan. ◆The impeller and guide vane body are equipped with double sealing rings. ◆ Surface hardening treatment to extend service life. When pumping solid special media, the sealing ring can be rinsed with external water. ◆The product structure design is flexible and can be customized according to user requirements. Outline Installation Drawing (Motor) Outline Installation Drawing (diesel engine)